Ducane sells both gas and oil furnaces. Most of its gas furnaces have received a 95% AFUE efficiency rating, which ultimately helps you pay less when operating the furnace. Affinity ® 3100/3200/4100/4200 NG (2006-2008). Affinity ® 3100/4100 LP (2009-2011). Affinity ® 3100/4100 NG (2009-2011). Seer, 2hp13, Split system heat pump. Read online or download PDF. Ducane (HVAC) 2HP13 User Manual Manuals Directory ManualsDir.com - online owner manuals library Search.
Safety Precautions
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations. Have
fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to
1.Always wear proper personal protection equipment.
2.Always disconnect electrical power before removing
3.Keep hands and clothing away from moving parts.
4.Handle refrigerant with caution, refer to proper MSDS
5.Use care when lifting, avoid contact with sharp edges.
NOTE:In some cases noise in the living area has been
traced to gas pulsations from improper installation
1.Locate unit away form windows, patios, decks, etc.
2.Ensure that vapor and liquid tube diametersare
3. Run refrigerant tubes as directly as possible by
4.Leave some slack between structure and unit to
5.When passing refrigerant tubes through the wall, seal
6.Avoid direct tubing contact with water pipes, duct work,
floor joists, wall studs, floors, walls, and any structure.
7.Do not suspend refrigerant tubing from joists and studs
with a rigid wire or strap which comes in direct contact
Ducane Hvac 2hp13 User's Manual Free
8.Ensure that tubing insulation is pliable and completely
When outdoor unit is connected to factory-approved
indoor unit, outdoor unit contains system refrigerant charge
for operation with indoor unit of the same size when
connected by 15 ft. of field-supplied tubing. For proper unit
operation, check refrigerant charge using charging
IMPORTANT:Maximum liquid-line size is 3/8 in. O.D. for
lines.
Outdoor Section
the condensing unit can be installed from the property line.
The outdoor section is to be installed on a solid
foundation. This foundation should extend a minimum of
2' (inches) beyond the sides of the outdoor section. To
reduce the possibility of noise transmission, the foundation
slab should NOT be in contact with or be an integral part of
This product and/or the indoor unit that is
Disturbing the insulation during installation,
fiberglass wool dust. (Fiberglass wool is known
Fiberglass wool may also cause respiratory,
To reduce exposure to this substance or for
sheets available from your distributor.
These instructions and warranty are to be given
Ducane Hvac 2hp13 User's Manual Pdf
handler unit.
Before installing, modifying, or servicing system,
OFF position. There may be more than 1
Ducane Hvac 2hp13 User's Manual Diagram
a suitable warning label. Electrical shock can