Ge Concord Superbus 2000 User Manual
Concord ® 4 is a full-featured security system for residential and commercial intrusion as well as residential fire detection that complies with false alarm standards. Easy to install and simple to use, Concord's modular design and advanced software provide outstanding system flexibility to meet the needs of virtually any residential or commercial security application. Ge Concord 4 Series Pdf User Manuals. View online or download Ge Concord 4 Series User Manual. Manuals; Brands; GE Manuals; Security System; Concord 4 Series; Ge Concord 4 Series Manuals Manuals and User Guides for GE Concord 4 Series. We have 2 GE Concord 4 Series manuals available for. SuperBus 2000 Transceiver Module.
- Ge Concord Superbus 2000 User Manual Online
- Ge Concord Superbus 2000 User Manual Youtube
- Ge Concord Superbus 2000 User Manual Pdf
- Ge Concord Superbus 2000 User Manual 2017
- Superbus 2000 Automation Module
3. Splice the 4-conductor cable wires to the matching colored
wires located on the touchpad wiring harness.
Find your panel in the next section for specific wiring
instructions.
Wiring Panels
Concord/Concord Express/Concord Ultra Panels
1. Connect the touchpad wiring to the panel terminals as
shown in Figure 3 below. Wire multiple touchpads in
parallel.
2. If desired, connect an optional hardwire switch to the
yellow touchpad wires as shown in Figure 3 below.
Concord Express Systems- Wire a 2K ohm EOL resistor
(49-467) in series with normally closed switches and in
parallel with normally open switches (see Figure 3 below).
Concord Systems with software version 2.0 or newer-
Wire a 2K ohm EOL resistor (49-467) in series with
normally closed switches and in parallel with normally
open switches (see Figure 3 below).
Concord Systems with software versions 1.0–1.6 - This
switch must be unsupervised and a resistor must not be
used.
Note: The optional touchpad hardwire input must be
added to panel memory. See the Concord/Concord
Express panel Installation Instructions for setting the
configuration.
3. Insert the touchpad wiring harness connector onto the pins
located on the rear of the unit. Make sure the yellow wires
are to the left, as shown.
Figure 3: Wiring the touchpad to Concord and Concord Express
panels
3
4
5
6
GND
+12V
BUS
BUS
B
BUS
A
PANEL TERMINALS
NOT
USED
OPTIONAL
N/C SWITCH
WITH MAGNET
YELLOW
BLACK
RED
WHITE
GREEN
TOUCHPAD
WIRING HARNESS
49-430
TAB
SLOT (3)
OPTIONAL
N/O SWITCH
WITH MAGNET
2K OHM
EOL RESISTOR
(Concord 2.0 or later
and Concord
Express panels)
SHIELDED
CABLE
Connect Shield
to Earth Ground
Advent Panels
Ge Concord Superbus 2000 User Manual Online
1. Splice the touchpad wiring to the panel SuperBus wiring
harness as shown in Figure 4 below. Wire multiple
touchpads in parallel.
2. If desired, connect an optional hardwire switch to the
yellow wires on the touchpad wiring harness. Wire a 2K
ohm EOL resistor (49-467) in series with normally closed
switches and in parallel with normally open switches (see
Figure 4 below).
Note: The optional touchpad hardwire input must be
added to panel memory. See the Advent panel Installation
Instructions for setting the configuration.
3. Insert the touchpad wiring harness connector onto the pins
located on the rear of the unit. Make sure the yellow wires
Figure 4: Wiring the touchpad to Advent panels
NOT
USED
YELLOW
TOUCHPAD
WIRING HARNESS
49-430
SPLICE
PANEL SUPERBUS
WIRING
HARNESS 49-462
BL
ACK (
G
ND)
WHI
T
E
(
B
US
B)
GREE
N (
B
US
A)
RED (
+
1
2
VDC)
TO ADDITIONAL
SUPERBUS
TOUCHPADS
AND/OR
MODULES
TAB
SLOT (3)
OPTIONAL
N/C SWITCH
WITH MAGNET
2K OHM
EOL RESISTOR
OPTIONAL
N/O SWITCH
WITH MAGNET
Connect Shield
to Earth Ground
SHIELDED
CABLE
UltraGard Panels
1. Connect the touchpad wiring to the panel terminals as
shown in Figure 5 on page 4. Wire multiple touchpads in
parallel.
2. If desired, connect an optional hardwire switch to the
yellow touchpad wires as shown in Figure 5 on page 4
(unsupervised in UltraGard systems).
Note: The optional touchpad hardwire input must be
added to panel memory. See the UltraGard panel
Installation Instructions or Reference Manual for setting
the configuration.
3. Insert the touchpad wiring harness connector onto the pins
located on the rear of the unit. Make sure the yellow wires
are to the left
SuperBus 2000 2X20 LCD Alphanumeric Touchpad Installation Instructions
3
•
Follow the wire length limits outlined in the specific panel
Installation Instructions between the touchpad and control
panel.
The following must be observed in UL installations
•
The touchpad hardwire input must not be used for fire
alarm initiating devices.
•
Only UL-listed devices may be connected to the touchpad
hardwire input.
•
Ge Concord Superbus 2000 User Manual Youtube
The touchpad hardwire input can be configured for
normally closed or normally open protection devices.
•
For UL installations with UltraGard and Concord (software
versions 1.0–1.6) panels, do not use the touchpad
hardwire input.
Tools Needed
• Drill
with
bits
• Screwdrivers
•
#6 screws and anchors (included)
•
Panhead screws for a gang box installation
•
Saw or utility knife for cutting wallboard
Note: Do not use screws larger than #6 or the touchpad
will not seat properly onto the back-plate.
Installation
The touchpad can be installed on a wall or in a gang box.
Chevrolet Tahoe/Suburban Owner Manual (GMNA-Localizing-U.S./Canada/ (4,1) Mexico-6081502) - 2014 - crc2 - 9/17/13 iv Introduction Danger, Warnings, and Cautions Warning messages found on vehicle labels and in this manual describe hazards and what to do to avoid or reduce them. Danger indicates a hazard with a high level of risk which will result in. Chevrolet Silverado Owner Manual (GMNA-Localizing-U.S./Canada/Mexico- Black plate (3,1) 5853506) - 2014 - CRC 3rd Edition - 8/29/13 Introduction iii. 2014 chevy tahoe lt owners manual. View and Download Chevrolet Tahoe 2014 specifications online. Tahoe 2014 Automobile pdf manual download. Also for: Suburban 2014. Chevrolet Spark Owner Manual (GMNA-Localizing-U.S./Canada-5853490) - Black plate (5,1) 2014 - crc - 9/3/13 Introduction v Symbols The vehicle has components.
To mount the touchpad on a wall:
1. Separate the mounting bracket from the back-plate by
loosening the two bottom screws and unlatching the tabs
from the mounting slots (see Figure 1 below).
2. Place the back-plate on the wall and mark the four
mounting holes and the wire access hole (see Figure 2
below). Be sure to leave a 1-inch clearance on all sides of
the back-plate.
3. Drill holes and insert appropriate anchors.
4. Secure the back-plate to the wall with included screws.
5. Cut a hole in the wall where the wire access hole was
marked to pull your cable through.
Figure 1: Touchpad mounting slots
MOUNTING SLOTS
CABLE OPENING
Ge Concord Superbus 2000 User Manual Pdf
OPENING FOR CONNECTOR
3101G03B.DSF
LOOSEN BOTTOM SCREWS (X2)
To mount the touchpad in a gang box:
1. Separate the mounting bracket from the back-plate by
loosening the two bottom screws and unlatching the tabs
from the mounting slots (see Figure 1 above).
2. Line up the gang box mounting holes with the holes on the
Ge Concord Superbus 2000 User Manual 2017
gang box (see Figure 2 below).
3. Secure the back-plate to the gang box with panhead
screws.
Note: Do not overtighten screws or the back-plate may
bind and prevent the touchpad from mounting properly.
Figure 2: Back plate and mounting holes
3101G02B DS4
GANG BOX MOUNTING HOLES (X2)
BACK PLATE MOUNTING TABS (X3)
WALL MOUNTING HOLES (X4)
WIRE
ACCESS
HOLE
Wiring
Wiring consists of connecting the touchpad wiring harness to
the panel terminals. You may also connect an optional
hardwire sensor to the touchpad hardwire input wires.
Superbus 2000 Automation Module
Before You Begin
1. Disconnect the panel AC power transformer and backup
battery (turn off power switch on UltraGard panels).
2. Run a 4-conductor, 22-gauge wire cable from the panel to
the touchpad location.
2
SuperBus 2000 2X20 LCD Alphanumeric Touchpad Installation Instructions